VALVE SAMPLE FLOW TEST RESULTS

VALVE SAMPLE FLOW TEST RESULTS

Envirovalve submitted three valve samples for flow test evaluation to the National Board in July.  We are please to share the results of this testing as follows:

Envirovalve has successfully completed testing of the subject valve type in accordance of the provisions of paragraph UG-131(k) of Section VIII and paragraph (a)(2) of Code Case 2397.

The National Board will accept a KRg of no less than 3.71 for this valve type.

Now that we have completed the flow testing portion of our ASME Certification process, we have started manufacturing some valves to be used in the plant audit (first week of October) and Pressure testing (October).

We are still estimating having our certification by November 2013.